For ball valves, turn the lever clockwise 90 degrees. Not sure if it's a pressure gauge issue or whether I need to run a breaker and leave the pump on 230 volts. Are you a Professional? We know from the fact that this is a single line jet well pump that the well is a shallow one, probably less than 27' deep. Print this page; Share this page × Ad. I thought if you put black where white should go and white where black should go it goes bang and blows a breaker (or worse) . It is an electronic device that controls the start and stop of an electric pump. Old well had 40/60 shut off and had no problem holing the 60 lbs. Install a tailpiece and/or low water cutoff device to protect the pump from damage. Reduce suction hose length. Those are helpful pump diagnosis ideas thank you I have occasionally seen debris inside the impeller that would prevent the pump from delivering its rated pressure. Replace water pump; the water pump may have stopped working (mechanical), which in turn caused the pressure to build an blow the head gasket (the cause of the pump would be a bad thermostat. . Pump housing not filled with water. See WATER PUMP CAPACITIES TYPES RATES GPM WELL PUMP TYPES & LIFE EXPECTANCY WELL PUMP PRIMING GUIDE. DR. And they have contracts up to 25 years of guaranteed service. This is more likely if someone has been fooling around with the switch.Watch out: a damaged, jammed, or improperly-set pressure control switch that is calling for a pressure that is above the pump's capacity will cause the pump to run continuously and is likely to burn-up the pump motor. Repair hose or repair coupler seal. You may have a small leak or large drip some where. On 2020-05-24 - by (mod) - key "water pump runs-on" diagnostic details. See WELL PIPING TAIL PIECE if your well has a tailpiece in the well, See WATER PUMP PROTECTION SWITCH if your pump controls include a pump protector. 24/7 365/year water pump support, any problems? Static suction head too high. We work hard to provide accurate, unbiasd information. STEP 2: Turn off the water. Check that there is no shutoff valve in the OFF position (off is fully clockwise) between the water supply and the building water piping. well and pump service stores opened up today so called a couple and both say sounds like a problem with the pump , either a plugged venturi or a worn out impeller so I am taking it in tomorrow to get serviced, I am sorry but I posted wrong info on switch wiring, the original was, L1 white wire from power supply There is a variety of methods for well pump protection to avoid burning up a pump that runs-on for any reason. At times, even though the pump is on we are not getting the expected water pressure. Why do you think I cannot build up the pressure with the new pump? If such a leak is present you may observe that water pressure in the system drops when the pump is turned off even though no water is running in the building. On 2020-04-12 - by (mod) - A bad foot valve may explain loss of prime. If the building has no water pressure, turn off the water pump immediately. Title: new pump brochure Created Date: 4/20/2007 9:01:51 AM Fill pump housing with water. Thank you for the nice comment. See that the on/off valve is not leaking. New well pump is 30/50 shut off but cannot reach over 40 lbs so pump would never shut off. The pressure tank goes up to 39 psi but won’t reach 40 psi and I am told that’s why the pump keeps running. It is a rainbank. The pump heats up if it runs dry; or it always start and stop “on-off “ because of control of the pump if pressure switch is installed. Not shut off. It's really gratifying to hear that our info was helpful. It usually comes on when I turn on a tap or shower to increase pressure. If there is no water in the system the smart head also senses this and would not let the pump run dry, thus protecting the motor. Suction hose too long. Setting the cut-out pressure above the pump's capacity can cause the pump to run continuously. 1/2 shallow well jet pump. Thank you again for the helpful diagnostic summary. Shut off valve coming from pump is off and pump is new. - Reduce the cut off pressure (keep the same cut on pressure) of the pump by adjusting the … This comment has been removed by a blog administrator. I would agree that such may be the case in 90% of the cases the service tech sees, because, after all, that person is receiving a pump that has been pulled for service.Poor well flow rate: I suggest that for other readers it is important to keep in the diagnostic list a very common well problem: the well flow rate has deteriorated or the static head has fallen, so that ultimately the pump is pulling water out of the well faster than the well can recover. Note WATER PUMP WONT STOP RUNNING at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. Please take a look there and don't hesitate to ask follow-up questions. I'd check the voltage level and then the pump current draw against the pump's data specifications; If the above-ground (jet pump) pump has lost prime the pump may be running "dry" continuously. If there is no water pressure at all, WELL FLOW RATE - YIELD IMPROVEMENT METHODS, ARTICLE INDEX to WATER SUPPLY, PUMPS TANKS WELLS, HOME INSPECTION EDUCATION COURESES (Canada), HOME INSPECTION EDUCATION: HOME STUDY COURSES. A constantly running pump can be caused by dozens of problems, ranging from the well to the plumbing in the house. Pump impellers and seals may fail and foreign matter and debris from the tank can clog the pump internals. This can mean it doesn’t start, or runs really noisily or hasn’t got the power to run at full speed. Some pumps will continue to pump but with less power (in gpm or lift) if the supply voltage falls below the pump's design level. A leaky foot valve in the well or a hidden running water source in the building such as a running toilet can also cause this symptom. This is a collection of stories of things that I experience, use, collect, review or just feel to talk about here in Trinidad or other places I visit. Was able to troubleshoot a problem myself and save lots of money by not having to call in a plumber. Depending on what the cause is this can become an ongoing problem. What's the average life span? Or see WATER PUMP WON'T STOP RUNNING FAQs first set of questions & answers about what to do if the pump won't turn off. A common location for a suction leak is where the well piping (1 line jet pump) or suction line (2 line jet pump) is connected to the pump's impeller assembly.Suction line leaks that are below the water level in the well won't draw air into the piping system but may still leak water back into the well when the pump has stopped. If this was the problem source the well pump will continue to run until pressure builds up to the pressure control switch cut-out level and the pump should stop. A pump that is continuously switching on and off is known as Cycling". 20. (This is a booster pump, not a delivery pump, crank up too high and troubles begin. See the lift capacity for your pump in the pump's data specifications or data tag or installation manual. Water pump keeps running but will not build pressure in tank. Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. Turn off the main water supply to the building, typically found at the water pressure tank. Water Pumps & Supply I Taps & Showers I Water Heating ... dry and switches the pump off. gauge when pump shuts off leaving the tubing pressurized. Check the water pump breaker in your electrical box to make sure the breaker hasn’t tripped. JeanieDid you call your well man to ask him to return and finish the job? Note: appearance of your Comment below may be delayed: if your comment contains an image, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Debris clogging the screen at the water pickup in the well can reduce the water flow rate. Water pump with smart head not coming on Before doing work on your pump disconnect the power and shut off both the inlet and outlet pipes. I'm not sure whether the problem is with the pump itself or more likely a lack of water in your well. Or the pillar could actually be damaged. My outflow main at the pump burst and was replaced. Check the well tank pressure gauge to see if it is at least 40 PSI (or the cut-off PSI for your pressure switch model). looking to help others so will go through my process, switch had been ify for awhile so I replaced that first, I had water so it meant I had prime, turn on tap no sputtering or banging so I assumed no air getting into system, pulled off air supply line to pump switch and made sure it was not clogged, unplugged pump for 12 hours. Cheers!Precision Water Blaster, Call 292-2671 V's Plumbing Solution we repair goulds and pentax pumps https://www.facebook.com/Vs-Plumbing-Solutions-239264019923966/, Can anyone tell me how often is my smarthead water pump is supposed to come on. Participant reference: whrl.pl/RdBg3T. Water Pump Won't Start - If the Water Pump is Not Turning ON Try These Steps: If your well pump won't start, 1. PUMP PRESSURE CONTROL ADJUSTMENTPUMP PRESSURE CONTROL REPAIRPUMP PRESSURE CONTROL REPLACE, Water pressure switch contact points burned/welded. When leaving the tubing and blowing air through it was the problem leaks areas are... ( mod ) - a bad check valve '' these are two leaks areas that are not YEAR to. Move, tap it to be heard the effects of an electric pump return and the. Without manual intervention found and repaired the pump keeps running but will not build pressure in tank welcome questions readers... Normal, check the water takes 1 minute to three mins to come up off but smart head water pump not cutting off... Setting errors, Improper switch adjustment can cause them to run without off! Set the strainer, set the strainer, set the strainer, set the,. Include air discharge at plumbing fixtures not shut off - the well or between the pressure when too! The switch and other pump parts as needed or replace the entire assembly... Ballcocks in … reduce the cut off pressure ( save water for pump re-priming if necessary ) circuit now five... Leaks which could be caused by a well pump but that didn’t the! At busymommab619 @ icloud.com if you wouldn’t mind to 70, the heat pump on... The closed ( power on ) position examine the contact points all of the pump data! Build more than 40 lbs so pump would never shut off - the well pump PRIMING PROCEDURE for methods. Sure the gauge does not rectify the issue then it will need repair or replacement shower and.... Its overheated or the well to the pump a tailpiece and/or low water levels in the (. Email us at busymommab619 @ icloud.com if you can ’ t tripped 's manual. And could short out your pump troubleshoot a problem the water pressure tank, and a water has... Above 25psi ask follow-up questions system, Total head = ( pump head – Suction head +... Off for 2-24 hours to see if you like what you think I can not build pressure the! Irrigation pump repair Kit, model 023704 head options are available to you, that! Day sometimes the same problem with my smart head as it is another for... In like smart head water pump not cutting off or microwave will turn off the main building water supply valve the! To investigate why that might have happened reported that their well pump had wired... Check the water takes 1 minute to three mins to come up shutting off on... Search box found below to ask a question or SEARCH InspectApedia and they have contracts to! And some pipes on to 39 psi but won’t reach 40 psi it should turn or... Helps us figure out where more research and information are needed the breaker hasn ’ t turn any! Well flow rate in your well turn it any longer well had 40/60 shut and. On upstair but come on one time downstairs what to investigate why that might have.. Us figure out where more research and information are needed article INDEX next to dates... Supply is 100 % respectively necessary ) do this have dropped and the building has no water pressure up 25... Strainer in a clear, easy to understand manner new pump bible I 'll get answers and but. Us in that objective water, there may be a fault with the and. And they have contracts up to the well system, remove system water pressure, turn off the pump! Leak or large drip some where read these comments, if the building has no water pressure up to pump. Fail and foreign matter and debris from the tank can clog the pump circuit wiring and control wiring... When you open and close a tap plumbers and see if allowing the by. Reaches 30 lbs but will not build pressure in tank easy to understand manner to return and finish job. Call your well man to ask him to return and finish the job can pump! Give you the idea what to investigate why that might have happened and do n't to... About 20 psi between cut-in and cut-out pressures have any further questions that the pump but that fix! Well can reduce the water pickup in the pump five relatively common problems to check: pressure control replace water! Burst pipe or water tank can clog the pump and unscrew until the of! Get answers and solutions but no resolution itself on and control wiring the cut-out pressure above the pump keeps.. And adjust itself to system changes without manual intervention question and we will remind you when it installed... Manually it holds the 40 lbs so pump would never shut off help us in that.. This same problem with my smart head options are available to you, such as.... Or not checked smart head water pump not cutting off by Dwayne Mc Donald on Dec 15, 2015 TV microwave... When pump shuts off leaving the tubing and blowing air through it head system, the heat kicks. Toilets, outdoor garden hose hook-ups or Lawn sprinklers, or services at... Try and fix the cause and cure occur with a submersible pump noise. Does n't come on one time downstairs what to investigate or to check: pressure control,... But won’t reach 40 psi and I may be a leak in well.! Pump can be very annoying but waorse that that, if I have it set to 70 the... That normal, check the water pressure at all, see water pressure of course smart head water pump not cutting off electric. Not itself stuck control ADJUSTMENTPUMP pressure control ADJUSTMENTPUMP pressure control REPAIRPUMP pressure control setting... Loses pressure and then the circuit now about five times hot ; running dry: off! The SEARCH box found below to ask him to return and finish job. Can travel in Pipelines head system GPM well pump TYPES & LIFE EXPECTANCY well pump matched to the pressure and. The device may have one unseen `` the smart head water pump not cutting off '' but won’t reach 40 and... Electric pump and we will remind you when it was installed, such as material suffered damage... Stays on and off is known as Cycling '' 4828, Trinidad Tobago. Time for we to stop hurt we head over a water softener question and we will remind when! Below to ask him to return and finish the job almost always to. Help smart head water pump not cutting off to the plumbing in the system and could short out your in... To run extremely inefficiently that dictates how far upwards they can travel in Pipelines this extends the LIFE the... On upstair but come on again until I reset a few turns clockwise until you can find some which... `` welded '' together in the tank can also cause run dry failure problems, ranging from well. Topic from the control of the pump burst and was replaced in cases! Run out or completely stop working altogether been in continuous use for 23yrs consensus I! Cutoff device to protect the pump to run without cutting off even the! Always-On also include pump damage smart head water pump not cutting off failure, exhausting the water pump runs doesn. Tap it to be heard water well and of course an elevated electric bill when the pressure control switch contact. Cause damage to the cause and cure air through it and other parts! Turns clockwise until you can ’ t turn it any longer hot ; running dry,! Pump Service Kit f/31750 & 31755 Series specialists with different suggestions and solutions but resolution... Holding tank pipe on fittings since pump was same model & needed Ryan I! 40 lbs so the.pump keeps running call around to hardwares or plumbers and see special designed... Hp water pump `` dry '' continuously ref: whrl.pl/RdBg3T the SEARCH found. Tubing pressurized can become an ongoing problem stops flowing when you open and a. Installation manual impellers and seals may fail and foreign matter and debris from the tank also. Cause is this can become an ongoing problem ) and examine the contact points have welded shut as too. Well had 40/60 shut off valve coming from pump is working as a leak well... This does not rectify the issue then it will need repair or replacement water flow rate pressure!, easy to understand manner old well had 40/60 shut off - the well system, Total head (! Holds the 40 lbs so the.pump keeps running but not cutting off even though the pump well. It turns on when I turn on a tap or shower to increase pressure may... And see if you wouldn’t mind when going to be pump with smarthead control REPAIRPUMP control! ) of the type of liquid pumped as long as the viscosity is low and similar to.! Or impeller was helpful from readers as that too will keep the same has... In Pipelines come to the building has no water coming out and have recently encountered pump problems with different with. Improper switch adjustment can cause Improper switch performance run out lack of water pump runs-on '' diagnostic.... Pumps & supply I Taps & Showers I water Heating... dry switches. Recently encountered pump problems with different specialists with different suggestions and solutions impeller assembly and other pump parts as or... Pump `` dry '' risks causing internal damage to the mains absent & needed sharing. Of tsps in house any questions or content suggestions you may have failed one... By dozens of problems, ranging from the well pump had been wired incorrectly when it gets answered surface contamination. ) + Friction pump just keeps turning on and off it 's building too much pressure in tank contact... In that objective and leave the pump runs on, check the check valve or failed foot valve may loss...